Carbon Infrared Emitters meet the Challenge of New Lacquer Formulation

Carbon Infrared Emitters meet the Challenge of New Lacquer Formulation

A carbon infrared system is curing successfully a coating on the longitudinal weld of metal cans

A carbon infrared system from Heraeus Noblelight has proved successful in curing a lacquer applied to the longitudinal weld of metal containers at the Aintree manufacturing plant of Crown Packaging. The system was developed when the existing foil heating system was unable to meet the stringent curing requirements of a new lacquer formulation.

The installation has also allowed other benefits, notably a reduction in line downtime as the previous foil system required considerable maintenance.

Crown Packaging is a company within Crown Holdings Inc, the leader in metal packaging technology, with operations at 139 plants located globally in 41 countries. The Aintree plant manufactures containers for a wide range of products from industrial oils to foodstuffs, such as maple syrup. After being cut and formed from sheet material, the cans are longitudinally welded. It is then important that this weld is internally coated with a lacquer, to prevent contamination of any food products and to protect the weld from attack from aggressive contents. The lacquer is applied by spray and must then be cured.
Previous curing solutions have included Radio Frequency (RF) ovens and infrared foil heaters. However, when the lacquer formulation was up-graded, neither of these heating systems could achieve the correct cure. Consequently, Crown contacted Heraeus, who carried out proving tests with carbon infrared at their Neston Application Centre. These proved so successful that a small-scale test unit was supplied to Crown for on-site trials, which led to an 84kW carbon infrared (CIR) system being installed. This consists of three 28kW CIR modules, each fitted with two 14kW carbon infrared emitters. The infrared heat is applied from the outside of the container and the heat is conducted through the weld to cure the lacquer on the can inside. Each module“s output can be independently, manually regulated, so that heating profiles can be matched to specific can sizes. Alternatively, the line speed can be varied to vary the can dwell time under the heaters.
„Apart from ensuring the correct lacquer cure, the new system has also brought other significant benefits,“ says Paul Kavanagh, project engineer at Crown. „Unlike the previous foil system, which required considerable guarding to prevent unwarranted access, the new CIR modules are already totally sealed. In addition, we suffered considerable downtime when foils failed and had to be replaced. So far we have not had one CIR emitter failure.“

Heraeus, the precious metals and technology group headquartered in Hanau, Germany, is a global, private company with more than 160 years of tradition. Our fields of competence include precious metals, materials and technologies, sensors, biomaterials and medical products, quartz glass, and specialty light sources. In the financial year 2012 Heraeus generated product revenues of EUR4.2 billion and precious metal trading revenues of EUR16 billion. With more than 12,200 employees in over 100 subsidiaries worldwide, Heraeus holds a leading position in its global markets.

Heraeus Noblelight GmbH with its headquarters in Hanau and with subsidiaries in the USA, Great Britain, France, China and Australia, is one of the technology- and market-leaders in the production of specialist light sources. In 2012, Heraeus Noblelight had an annual turnover of 92,5 Million EUR and employed 715 people worldwide. The organization develops, manufactures and markets infrared and ultraviolet emitters and systems for applications in industrial manufacture, environmental protection, medicine and cosmetics, research, development and analytical measurement techniques.
Heraeus Noblelight acquired on January 31, 2013 the Fusion UV Systems group headquartered in Gaithersburg, Maryland (USA).

Kontakt:
Heraeus Noblelight GmbH
Dr. Marie-Luise Bopp
Reinhard-Heraeus-Ring 7
63801 Kleinostheim
+49 6181/35-8547
marie-luise.bopp@heraeus.com
http://www.heraeus-noblelight.com/infrared